SPECIFICATIONS |
MODEL | 7315 |
GROUND BOND |
Output AC Current | 1 - 30A |
Output AC Voltage | 6V, Maximum |
Output Frequency | 50Hz/60Hz ±100ppm, User Selection |
SETTINGS |
Max-Limit Range | Resistance | 0-510mΩ | 0-120mΩ |
AC Current | 1.00-10.00A | 10.1-30.00A |
Resolution | 1mΩ |
Accuracy | Same as Resistance Measurement Accuracy |
Min-Limit Range | Resistance | 0-510mΩ | 0-120mΩ |
AC Current | 1.00-10.00A | 10.1-30.00A |
Resolution | 1mΩ |
Accuracy | Same as Resistance Measurement Accuracy |
Lead Resistance Offset | Range | 0 - 100 mΩ, Auto/manual |
Resolution | 1mΩ |
Accuracy | ±(2% of setting +2 counts) |
Dwell Time | Range | 0, 0.5 - 999.9 sec (0 = continuous) |
Resolution | 0.1 sec |
Accuracy | ±(0.1% + 0.05sec) |
MEASUREMENT |
AC Current | Range | 1.00 - 30.00A |
Resolution | 0.01A |
Accuracy | ±(3%of reading +3counts) |
Resistance | Range | 0-510mΩ | 0-510mΩ | 0-120mΩ |
1.00-2.99A | 3.00-10.00A | 10.01-30.00A |
Resolution | 1 mΩ |
Accuracy | ±3% of reading+3 counts) | ±(2% of reading +2 counts) |
GENERAL |
Input Voltage AC | 115/230Vac±15%, 50/60Hz, Fuse 10A |
PLC Remote Control | Input: Test , Reset,Withstand Processing ,(Memory1.2.3,) Output: Pass , Fail , Processing , Reset Out , Start Out |
Memory | 10 memories, 3 steps/memory |
Display | 128×64 Graphic LCD |
Key Lock | To prevent unauthorized alteration of the test Parameters |
Calibration | Build-in software and external calibrated meters |
Verification | Build-in software driven verification menu to test fault detection circuits |
Alarm Volume Setting | Range: 0-9 ;0=OFF, 1 is softest volume, 9 is loudest volume. |
Environment | 0-40℃, 20-80%RH |
Dimension | 215(W)×89(H)×430(D)mm |
Net Weight | 8.7Kg |
STANDARD ACCESSORIES |
Power Cord(10A) | ×1 |
Fuses | ×2 (Including a spare contained in the fuse holder) |
Interlock Disable Key(1505) | ×1 |
Ground Bond Test Lead 30A,1.5m(1103) | ×1 |
Ground Bond Return Lead 30A,1.5m(1104) | ×1 |